2V 2500Ah Tubular Plate Opzs Battery 131 KG For Base Station 20 Opzs2500

Brand Name : CGB
Model Number : 20OPzS2500
Certification : CE/UL/ISO
Place of Origin : China
MOQ : 20pcs
Price : negotiation
Payment Terms : T/T or L/C
Supply Ability : 25000 pcs per month
Delivery Time : 30 days
Packaging Details : Packed in carton, and then reinforced with pallet or wooden case for outer packing
Product Name : 20OPzS2500
Application : Base Station
Voltage : 2V
Capacity : 2500AH
Size Of Battery : 487*212*771mm
Terminal : M8
Weight : 131 KG
Case : ABS, SAN
Contact Now

2V 2500Ah Tubular Plate Opzs Battery For Base Station 20 Opzs2500


Specifications:

Nominal Voltage2V
Nominal Capacity (C20)2500Ah (1.80V @ 20℃)
DimensionLength487mm
Width212mm
Height771mm
Total Height826mm
Weight(With Electrolyte)Approx. 183 kg
TerminalM8
Internal ResistanceFull charged@20℃: 0.0005 Ohm
Max Charging Current500A

Description:

● Designed life for floating charge is 20 years according to IEC60896-11;

● Rubber separator with floating electrolyte technology;

● High strength ABS material for cover and SAN material transparent container;

● Wide temperature scope of application (-15~45℃);

● Best temperature of application (20±5℃);

● Special filter installation for acid fog proof;

● Transparent container, convenient to observe;

● Super long service life.


Applications:

● Telecommunications

● Cable Television

● Electric Utility

● Alarm & Security system

● UPS

● Control Equipment

● Medical Equipment

● Railroad Utility

● Photovoltaic System

● Alternative Energy System

● High Power Backup Supply


Maintenance

● No organic solution into the battery room; let alone the battery.


● No puppy enters into the room to avoid the short circuit of the battery.


● Give periodically supplementary charge to the battery for long storage.


● No parallel use of the battery group with different capacities.


● Each setting parameter shouldn’t exceed the regular range of this manual.


● The temperature should not exceed 40 C in the usual use. No hot feeling when touching the joint point and the terminal.


Precautions

● The battery pack has high voltage, so direct contact or indirect contact through wet objects with any conducting cable may result in vital injury. The battery pack is energy-storing equipment, so never short-circuit the battery pack during operation and maintenance in any way.


● Do not wear watch, hand chain, bracelet, ring and other conductive objects during operation.


● Do use special tools.

Do use special tools, instead of common tools during electrical connections. In addition, keep the tools in good insulation condition (e.g. wrap insulating tape around the bare metal parts) before using them to avoid short circuit and personal injury caused by tool contact with any live objects.


● Using the batteries of the same model

Use batteries of the same model in the same set. Using different models in the same set will damage the equipment.


● The Operation Environment

The battery should be kept far away from fire, organic solution; avoid direct sunshine and the temperature should be the same of the same set.


Tips

● Provide free air space between batteries when more than two are grouped together. The recommended distance is 0.2" to 0.4" (5mm to 10mm).


● When batteries are connected together in a series parallel arrangement, the inter-connecting cables must be of equal length and resistance to insure equalization of the load.


● Do not crush, incinerate or dismantle the battery. The electrolyte contains sulfuric acid which can cause serious damage to eyes and skin. Should this occur, flush profusely with water and seek medical attention.


● Mixing batteries of different capacities, age and/or manufacture is not recommended. Please consult with an application engineer if it is unavoidably necessary.


● Battery life is dependent on its operating conditions. Please refer to the life curves published in this Applications Manual. These curves represent typical results under optimum operating conditions. Actual life will vary greatly due to variability of these conditions. To obtain optimum battery performance for standby service, CGB recommends that within five years of use, the batteries be replaced.


Product Tags:

flooded lead acid batteries

      

agm lead acid battery

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

2V 2500Ah Tubular Plate Opzs Battery 131 KG For Base Station 20 Opzs2500 Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Wuhan Changguang Battery Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0