Sign In | Join Free | My vivirlatino.com
vivirlatino.com
Wuhan Changguang Battery Co., Ltd
Wuhan Chang Guang Battery Co., Ltd ɑ. . . QUALITY IS PRIORITY ONE . . . QUALITY CONTINUUM . . .Ω
Home > UPS Lead Acid Battery >

Maintenance Free 12V 17AH Regulated Lead Acid Battery For UPS Energy

Wuhan Changguang Battery Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

Maintenance Free 12V 17AH Regulated Lead Acid Battery For UPS Energy

Brand Name : CGB
Model Number : CB12170
Certification : CE/UL/VDS/TLC/ISO
Place of Origin : China
MOQ : 300 pcs
Price : negotiation
Payment Terms : T/T or L/C
Supply Ability : 135000 pcs per month
Delivery Time : 30 days
Packaging Details : Packed in carton, and then reinforced with pallet or wooden case for outer packing
Product Name : CB12170
Application : Energy Storage
Voltage : 12V
Capacity : 17AH
Size Of Battery : 181*76*167mm
Terminal : FP-01/RT-08
Weight : 5.85KG
Case : ABS-HB,V0
Contact Now

Maintenance Free 12V 17AH Regulated Lead Acid Battery For UPS Energy


Description


Designed life for floating charge is 3~5 years (20℃);


AGM valve regulated sealing technology;


Wide temperature scope of application (-15~45℃);


Best temperature of application (20±5℃);


Multipurpose: Float or Cyclic use


High strength ABS material for container & lid;


Standing or lying down for using, convenient to transport and install;


High sealed reaction efficiency, little loss of water, no need to add distilled

water or electrolyte, simple to use and maintain;


Low self-discharge rate.


Specification


Nominal Voltage12VCapacityC2017Ah (10.5V, at 25℃)
Nominal Capacity (C20)17Ah (10.5V,at 25℃)C1015.3Ah (10.5V, at 25℃)
DimensionLength 181mmC312.75Ah (10.5V, at 25℃)
Width 76mmC110.2Ah (10.2V, at 25℃)
Height 167mmInternal ResistanceApprox. 13 mΩ (25℃)
Total Height 167mmMax Short-duration Discharge Current510A(25℃)
WeightApprox. 5.85kgTerminalFP-01/RT-08/FO-21

Applications


Uninterruptable Power Supply (UPS)


Telecommunication


Emergency lighting


Fire alarm and security systems


Medical appliance


Solar applications


Electronic test equipment


Electronic measuring devices


Geophysical devices




Feature


Sealed Construction


The unique construction and sealing techniques ensure no electrolyte leakage


from case or terminals.


Electrolyte Suspension System


All batteries utilize an electrolyte suspension system consisting of a high


porosity, glass fiber material which in conjunction with plates, totally absorb and


contain the electrolyte.


Gas Recombination


CGB batteries incorporate a built-in design that controls gas generation and


induces recombination of more than 99% of gases generated during float or


cyclic usage.


Maintenance Free Operation


There is no need to check specific gravity of the electrolyte or add water to


batteries during float service life. In fact, there is no provision for this type of


maintenance.


Low Pressure Valve Regulated System..


All batteries are equipped with safety release valves, designed to operate


between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is


never an excessive accumulation of gas within the battery.


Heavy Duty Grids


Heavy duty lead calcium tin alloy grids provide an extra margin of performance


and service life in either float or cyclic applications.


Cyclic Service Life


More than 600 discharge/recharge cycles can be realized from CGB CB and HR


batteries, dependent on the average depth of discharge.


Float Service Life


SE and CB, HR Series batteries have an expected life span of 3 to 5 years in


float service applications.


Self Discharge - Shelf Life


The self discharge rate at room temperature is approximately 3% of rated

capacity per month.


Operating Temperature


CGB Batteries may be operated over a broad range of ambient temperatures.


Terminals


The batteries are manufactured using a range of terminals which vary in size


and type. Please refer to details as shown



Notice:

Don’t near the hot source and don’t under the sunshine.


Don’t charge in the sealed container.


No short circuit. It should be addition charge if you don’t use, and single charge

per three months, to avoid irreversible sulfating. The battery should be changed

when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.


Don’t store in the space of acid gas.


You should be careful and regular check when use the battery. To avoid the

battery don’t work. You should change the battery if the capacity is not full or has

been damage, especially after one year using.


Don’t put the battery in the fire, or it will explode.


Please use cotton cloth to clean, if the battery is broken down and leak

electrolyte. Please wash your skin when touch the electrolyte.


Don’t clean the battery by using the organic solution. (e.g. petrol)

ging time: 15~20h; Temperature compensation coefficient: -5mV/℃/cell.



Product Tags:

charging ups battery

      

flooded deep cycle battery

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Maintenance Free 12V 17AH Regulated Lead Acid Battery For UPS Energy Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Wuhan Changguang Battery Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0